PIE 235 Process Voltage Calibrator
$584.00
Process Voltage Calibrator
Add $500.00 to cart and get free shipping!
Description
Overview PIE 235 Process Voltage Calibrator
Process Voltage Calibrator
Features and Performance
- Source three ranges of mV & V dc plus percent of 1 to 5 volts With the 235 you can check, calibrate and measure all your voltage, millivolt and pH signal instruments in your plant. Source -500.00 to 999.00 mV, 1.000 to 5.000 V, -25.00 to 125.00% of 1 to 5 V; 0.000 to 20.000 V
- With the 235 you can check, calibrate and measure all your voltage, millivolt and pH signal instruments in your plant. Source -500.00 to 999.00 mV, 1.000 to 5.000 V, -25.00 to 125.00% of 1 to 5 V; 0.000 to 20.000 V
- Power your loops with over 1,000 Ohm loads The 20.000 V range has an extended span of up to 24.000 Volts giving you a portable source for powering your loops
- The 20.000 V range has an extended span of up to 24.000 Volts giving you a portable source for powering your loops
- Read DC volts The 235 can measure from -500.00 to 999.00 mV, 0.000 to 5.100 V, -25.0 to 125.0 % of 1 to 5 V; 0 to 20.000 V and 0.00 to 60.00 V DC. Use it to check loop power supplies, I/V converters, 1 to 5 Volt signals, and other voltages
- The 235 can measure from -500.00 to 999.00 mV, 0.000 to 5.100 V, -25.0 to 125.0 % of 1 to 5 V; 0 to 20.000 V and 0.00 to 60.00 V DC. Use it to check loop power supplies, I/V converters, 1 to 5 Volt signals, and other voltages
- Save time calibrating recorders and monitors in 4 to 20 mA loops Other brands of calibrators require that you break the loop to calibrate voltage inputs. With the PIE 235 you simply clip the test leads across the voltage inputs in a live 4 to 20 mA loop without disconnecting any wires
- Other brands of calibrators require that you break the loop to calibrate voltage inputs. With the PIE 235 you simply clip the test leads across the voltage inputs in a live 4 to 20 mA loop without disconnecting any wires
- Simulate pH probes into transmitters & analyzers Use the pH simulator to verify proper operation of pH devices before you place a probe into a calibrated buffer
- Use the pH simulator to verify proper operation of pH devices before you place a probe into a calibrated buffer
Why Choose This Product
The PIE 235 Process Voltage Calibrator is a model-specific voltage calibrator for calibration and test work.
Product Specifications
| Feature | Details |
|---|---|
| Range | Power your loops with over 1,000 Ohm loads The 20.000 V has an extended span of up to 24.000 Volts giving you a portable source for powering your loops |
| Range | The 20.000 V has an extended span of up to 24.000 Volts giving you a portable source for powering your loops |
Reviews (0)
Be the first to review “PIE 235 Process Voltage Calibrator” Cancel reply

Reviews
There are no reviews yet.